Attributes
| Part Number | 3237-000000-000000 |
|---|
Description
Plant Master™ 300NC Medium–duty air and water applications where a hose with high electrical resistance is needed. Non-conductive (Greater than 1 Megohm/in.). Storage and use may adversely affect electrical resistance. NOTE: For additional sizes or applications requiring oil-resistance see Plant Master XTreme. ARPM (Class C) Limited oil–resistant tube. ARPM (Class C) Limited oil–resistant cover.
Variations (4)
1/2X500 PLANT 300 NC
| Vacuum (In. Hg) | 25 |
|---|---|
| Continuous Operating Temperature Range | -20°F to +150°F |
| Minimum Bend Radius (in) | 5 |
| Minimum Bend Radius (mm) | 127 |
| Min. Burst Pressure (psi) | 1200 |
| Hose Inside Diameter (in). | 0.5 |
| Hose Inside Diameter (mm) | 12.7 |
| Hose Outside Diameter (in) | 0.88 |
| Hose Outside Diameter (mm) | 22.4 |
| Inside Diameter (in) | 0.5 |
| Inside Diameter (mm) | 12.7 |
| Working Pressure (psi) | 300 |
| Length (m) | 152.4 |
| Outside Diameter (in) | 0.88 |
| Outside Diameter (mm) | 12.7 |
| Color | Red |
| Reinforcement | Synthetic textile |
| Tube | EPDM - Type P. Limited oil resistance. |
| Construction: Cover | EPDM - Type P |
| Standards | Non-conductive (>1 Megohm/in.). Storage and use may adversely affect electrical resistance. |
| Standards: Cover | ARPM Class C |
| Standards: Tube | ARPM Class C |
| Notes | NOTE: For additional sizes or applications requiring oil-resistance see Plant Master® XTreme™. |
| Recommended For | Medium-duty air and water applications where a hose with high electrical resistance is needed. |
| Customer Pack | 500 |
| Weight (lbs.) | 0.24 |
3/4X500 PLANT 300 NC
| Vacuum (In. Hg) | 20 |
|---|---|
| Continuous Operating Temperature Range | -20°F to +150°F |
| Minimum Bend Radius (in) | 6 |
| Minimum Bend Radius (mm) | 152 |
| Min. Burst Pressure (psi) | 1200 |
| Hose Inside Diameter (in). | 0.75 |
| Hose Inside Diameter (mm) | 19.1 |
| Hose Outside Diameter (in) | 1.16 |
| Hose Outside Diameter (mm) | 29.5 |
| Inside Diameter (in) | 0.75 |
| Inside Diameter (mm) | 19.1 |
| Working Pressure (psi) | 300 |
| Length (m) | 152.4 |
| Outside Diameter (in) | 1.16 |
| Outside Diameter (mm) | 19.1 |
| Color | Red |
| Reinforcement | Synthetic textile |
| Tube | EPDM - Type P. Limited oil resistance. |
| Construction: Cover | EPDM - Type P |
| Standards | Non-conductive (>1 Megohm/in.). Storage and use may adversely affect electrical resistance. |
| Standards: Cover | ARPM Class C |
| Standards: Tube | ARPM Class C |
| Notes | NOTE: For additional sizes or applications requiring oil-resistance see Plant Master® XTreme™. |
| Recommended For | Medium-duty air and water applications where a hose with high electrical resistance is needed. |
| Customer Pack | 500 |
| Weight (lbs.) | 0.36 |
3/8X500 PLANT 300 NC
| Vacuum (In. Hg) | 30 |
|---|---|
| Continuous Operating Temperature Range | -20°F to +150°F |
| Minimum Bend Radius (in) | 3 |
| Minimum Bend Radius (mm) | 76 |
| Min. Burst Pressure (psi) | 1200 |
| Hose Inside Diameter (in). | 0.38 |
| Hose Inside Diameter (mm) | 9.5 |
| Hose Outside Diameter (in) | 0.75 |
| Hose Outside Diameter (mm) | 19.1 |
| Inside Diameter (in) | 0.38 |
| Inside Diameter (mm) | 9.5 |
| Working Pressure (psi) | 300 |
| Length (m) | 152.4 |
| Outside Diameter (in) | 0.75 |
| Outside Diameter (mm) | 9.5 |
| Color | Red |
| Reinforcement | Synthetic textile |
| Tube | EPDM - Type P. Limited oil resistance. |
| Construction: Cover | EPDM - Type P |
| Standards | Non-conductive (>1 Megohm/in.). Storage and use may adversely affect electrical resistance. |
| Standards: Cover | ARPM Class C |
| Standards: Tube | ARPM Class C |
| Notes | NOTE: For additional sizes or applications requiring oil-resistance see Plant Master® XTreme™. |
| Recommended For | Medium-duty air and water applications where a hose with high electrical resistance is needed. |
| Customer Pack | 500 |
| Weight (lbs.) | 0.19 |
33181300
No variation attributes.
Specifications
| Vacuum (In. Hg) | 20 – 30 |
|---|---|
| Continuous Operating Temperature Range | -20°F to +150°F |
| Minimum Bend Radius (in) | 3 – 6 |
| Minimum Bend Radius (mm) | 76 – 152 |
| Min. Burst Pressure (psi) | 1200 |
| Hose Inside Diameter (in). | 0.38 – 0.75 |
| Hose Inside Diameter (mm) | 9.5 – 19.1 |
| Hose Outside Diameter (in) | 0.75 – 1.16 |
| Hose Outside Diameter (mm) | 19.1 – 29.5 |
| Inside Diameter (in) | 0.38 – 0.75 |
| Inside Diameter (mm) | 9.5 – 19.1 |
| Working Pressure (psi) | 300 |
| Length (m) | 152.4 |
| Outside Diameter (in) | 0.75 – 1.16 |
| Outside Diameter (mm) | 9.5 – 19.1 |
| Color | Red |
| Reinforcement | Synthetic textile |
| Tube | EPDM - Type P. Limited oil resistance. |
| Construction: Cover | EPDM - Type P |
| Standards | Non-conductive (>1 Megohm/in.). Storage and use may adversely affect electrical resistance. |
| Standards: Cover | ARPM Class C |
| Standards: Tube | ARPM Class C |
| Notes | NOTE: For additional sizes or applications requiring oil-resistance see Plant Master® XTreme™. |
| Recommended For | Medium-duty air and water applications where a hose with high electrical resistance is needed. |
| Customer Pack | 500 |
| Weight (lbs.) | 0.19 – 0.36 |
PDF Documents
No PDF documents.