Fuel Master™ LP 350 Hose

Scraped SKU: 3220-000000-000001 Series: Fuel Master™ LP 350 Hose 2026-06-12 14:14:03

Attributes

Part Number3220-000000-000001

Description

Fuel Master™ LP 350 Hose RECOMMENDED FOR: Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit). CAUTION: Not recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744–5070 for inspection and assembly testing information. Warning: Do not convey LP Gas over +140°F (60°C). CAUTION: Not recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744–5070 for inspection and assembly testing information. Meets standards: UL No. 21, CAN/CGA-8.1-M86, NFPA 58 Section 8-3.5. Design Factor: 5:1

Variations (20)

1-1/4XRL FUEL LP350

Vacuum (In. Hg)10
Minimum Bend Radius (in)10
Minimum Bend Radius (mm)254
Inside Diameter (in)1.25
Inside Diameter (mm)31.8
Temperature Range-40°F to +180°F (-40°C to +82°C)
Working Pressure (psi)350
Length (m)91.4
Outside Diameter (in)1.85
Outside Diameter (mm)31.8
Coupling RecommendationGLX® Couplings [G44 Series]
ColorBlack
CoverChloroprene - Type A. Perforated.
Reinforcement3-braid, textile
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
Construction: Design Factor5:1
Construction: Reinforcement3-braid, textile
Construction: TubeNitrile - Type C. Black. High oil resistance

8FM7000

Vacuum (In. Hg)25
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)5
Minimum Bend Radius (mm)127
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.5
Hose Inside Diameter (mm)12.7
Hose Outside Diameter (in)0.91
Hose Outside Diameter (mm)23.1
Inside Diameter (in)0.5
Inside Diameter (mm)12.7
Working Pressure (psi)350
Length (m)213.3
Outside Diameter (in)0.91
Outside Diameter (mm)12.7
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack700
Weight (lbs.)0.28

4FM7000

Vacuum (In. Hg)30
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)3
Minimum Bend Radius (mm)76
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.25
Hose Inside Diameter (mm)6.4
Hose Outside Diameter (in)0.58
Hose Outside Diameter (mm)14.7
Inside Diameter (in)0.25
Inside Diameter (mm)6.4
Working Pressure (psi)350
Length (m)1127.7
Outside Diameter (in)0.58
Outside Diameter (mm)6.4
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack3700
Weight (lbs.)0.14

4FM7001

Vacuum (In. Hg)30
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)3
Minimum Bend Radius (mm)76
Hose Inside Diameter (in).0.25
Hose Inside Diameter (mm)6.4
Hose Outside Diameter (in)0.58
Hose Outside Diameter (mm)14.7
Inside Diameter (in)0.25
Inside Diameter (mm)6.4
Temperature Range-40°F to +180°F (-40°C to +82°C)
Working Pressure (psi)350
Length (m)213.3
Outside Diameter (in)0.58
Outside Diameter (mm)6.4
Coupling RecommendationGLX® Couplings [G44 Series]
UseIndustrial Hose
ColorBlack
CoverChloroprene - Type A. Perforated.
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
Construction: Design Factor5:1
Construction: Reinforcement4-spiral, fiber
Construction: TubeNitrile - Type C. Black. High oil resistance
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Couplings NoteSelect Ind Hose Coupling Reference Sheet link below for additional information.
Customer Pack700
Weight (lbs.)0.14

16FM7000

Vacuum (In. Hg)15
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)8
Minimum Bend Radius (mm)203
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).1
Hose Inside Diameter (mm)25.4
Hose Outside Diameter (in)1.51
Hose Outside Diameter (mm)38.4
Inside Diameter (in)1
Inside Diameter (mm)25.4
Working Pressure (psi)350
Length (m)30.5
Outside Diameter (in)1.51
Outside Diameter (mm)25.4
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack100
Weight (lbs.)0.66

16FM7001

Vacuum (In. Hg)15
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)8
Minimum Bend Radius (mm)203
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).1
Hose Inside Diameter (mm)25.4
Hose Outside Diameter (in)1.51
Hose Outside Diameter (mm)38.4
Inside Diameter (in)1
Inside Diameter (mm)25.4
Working Pressure (psi)350
Length (m)38.1
Outside Diameter (in)1.51
Outside Diameter (mm)25.4
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack125
Weight (lbs.)0.6

16FM7002

Vacuum (In. Hg)15
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)8
Minimum Bend Radius (mm)203
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).1
Hose Inside Diameter (mm)25.4
Hose Outside Diameter (in)1.51
Hose Outside Diameter (mm)38.4
Inside Diameter (in)1
Inside Diameter (mm)25.4
Working Pressure (psi)350
Length (m)45.7
Outside Diameter (in)1.51
Outside Diameter (mm)25.4
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack150
Weight (lbs.)0.6

16FM7003

Vacuum (In. Hg)15
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)15
Minimum Bend Radius (mm)381
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).1
Hose Inside Diameter (mm)25.4
Hose Outside Diameter (in)1.51
Hose Outside Diameter (mm)38.4
Inside Diameter (in)1
Inside Diameter (mm)25.4
Working Pressure (psi)350
Length (m)61
Outside Diameter (in)1.51
Outside Diameter (mm)25.4
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack200
Weight (lbs.)0.63

16FM7004

Vacuum (In. Hg)15
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)8
Minimum Bend Radius (mm)203
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).1
Hose Inside Diameter (mm)25.4
Hose Outside Diameter (in)1.51
Hose Outside Diameter (mm)38.4
Inside Diameter (in)1
Inside Diameter (mm)25.4
Working Pressure (psi)350
Length (m)106.7
Outside Diameter (in)1.51
Outside Diameter (mm)25.4
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack300
Weight (lbs.)0.6

2X50 FUEL LP350

Vacuum (In. Hg)10
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)14
Minimum Bend Radius (mm)356
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).2
Hose Inside Diameter (mm)50.8
Hose Outside Diameter (in)2.86
Hose Outside Diameter (mm)72.6
Inside Diameter (in)2
Inside Diameter (mm)50.8
Working Pressure (psi)350
Length (m)15.2
Outside Diameter (in)2.86
Outside Diameter (mm)50.8
ColorBlack
Reinforcement3-braid, textile
TubeChloroprene - Type A. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack50
Weight (lbs.)1.84

12FM7000

Vacuum (In. Hg)20
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)6
Minimum Bend Radius (mm)152
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.75
Hose Inside Diameter (mm)19.1
Hose Outside Diameter (in)1.23
Hose Outside Diameter (mm)31.2
Inside Diameter (in)0.75
Inside Diameter (mm)19.1
Working Pressure (psi)350
Length (m)30.5
Outside Diameter (in)1.23
Outside Diameter (mm)19.1
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack100
Weight (lbs.)0.44

12FM7001

Vacuum (In. Hg)20
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)6
Minimum Bend Radius (mm)152
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.75
Hose Inside Diameter (mm)19.1
Hose Outside Diameter (in)1.23
Hose Outside Diameter (mm)31.2
Inside Diameter (in)0.75
Inside Diameter (mm)19.1
Working Pressure (psi)350
Length (m)45.7
Outside Diameter (in)1.23
Outside Diameter (mm)19.1
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack150
Weight (lbs.)0.44

12FM7002

Vacuum (In. Hg)20
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)6
Minimum Bend Radius (mm)152
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.75
Hose Inside Diameter (mm)19.1
Hose Outside Diameter (in)1.23
Hose Outside Diameter (mm)31.2
Inside Diameter (in)0.75
Inside Diameter (mm)19.1
Working Pressure (psi)350
Length (m)106.7
Outside Diameter (in)1.23
Outside Diameter (mm)19.1
UseIndustrial Hose
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack350
Weight (lbs.)0.44

6FM7000

Vacuum (In. Hg)30
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)3
Minimum Bend Radius (mm)76
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.38
Hose Inside Diameter (mm)9.5
Hose Outside Diameter (in)0.74
Hose Outside Diameter (mm)18.8
Inside Diameter (in)0.38
Inside Diameter (mm)9.5
Working Pressure (psi)350
Length (m)609.6
Outside Diameter (in)0.74
Outside Diameter (mm)9.5
ColorBlack
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack2000
Weight (lbs.)0.21

6FM7001

Vacuum (In. Hg)30
Continuous Operating Temperature Range-40°F to +180°F
Minimum Bend Radius (in)3
Minimum Bend Radius (mm)76
Hose Inside Diameter (in).0.38
Hose Inside Diameter (mm)9.5
Hose Outside Diameter (in)0.74
Hose Outside Diameter (mm)18.8
Inside Diameter (in)0.38
Inside Diameter (mm)9.5
Temperature Range-40°F to +180°F (-40°C to +82°C)
Working Pressure (psi)350
Length (m)213.3
Outside Diameter (in)0.74
Outside Diameter (mm)9.5
Coupling RecommendationGLX® Couplings [G44 Series]
UseIndustrial Hose
ColorBlack
CoverChloroprene - Type A. Perforated.
Reinforcement4-spiral, fiber
TubeNitrile - Type C. High oil resistance.
Construction: CoverChloroprene - Type A
Construction: Design Factor5:1
Construction: Reinforcement4-spiral, fiber
Construction: TubeNitrile - Type C. Black. High oil resistance
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Couplings NoteSelect Ind Hose Coupling Reference Sheet link below for additional information.
Customer Pack700
Weight (lbs.)0.21

4FM7000

No variation attributes.

6FM7000

No variation attributes.

32210092

No variation attributes.

32203206

No variation attributes.

32201501

No variation attributes.

Specifications

Vacuum (In. Hg)10 – 30
Minimum Bend Radius (in)3 – 15
Minimum Bend Radius (mm)76 – 381
Inside Diameter (in)0.25 – 2
Inside Diameter (mm)6.4 – 50.8
Temperature Range-40°F to +180°F (-40°C to +82°C)
Working Pressure (psi)350
Length (m)15.2 – 1127.7
Outside Diameter (in)0.58 – 2.86
Outside Diameter (mm)6.4 – 50.8
Coupling RecommendationGLX® Couplings [G44 Series]
ColorBlack
CoverChloroprene - Type A. Perforated.
Reinforcement3-braid, textile, 4-spiral, fiber
TubeNitrile - Type C. High oil resistance., Chloroprene - Type A. High oil resistance.
Construction: CoverChloroprene - Type A
Construction: Design Factor5:1
Construction: Reinforcement3-braid, textile, 4-spiral, fiber
Construction: TubeNitrile - Type C. Black. High oil resistance
Continuous Operating Temperature Range-40°F to +180°F
Min. Burst Pressure (psi)1750
Hose Inside Diameter (in).0.25 – 2
Hose Inside Diameter (mm)6.4 – 50.8
Hose Outside Diameter (in)0.58 – 2.86
Hose Outside Diameter (mm)14.7 – 72.6
UseIndustrial Hose
StandardsCAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes).
Recommended For
Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit).
CautionNot recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information.
Customer Pack50 – 3700
Weight (lbs.)0.14 – 1.84
Couplings NoteSelect Ind Hose Coupling Reference Sheet link below for additional information.

PDF Documents

No PDF documents.